    SOETECK delivers professional UPS system solutions for power protection needs ranging from edge computing nodes to hyperscale data centers. Our customized services are tailored to your actual business scenarios, featuring modular design, intelligent redundancy configuration and energy efficiency optimization to build highly reliable and available power protection systems. Expert engineering teams provide end-to-end services from solution design to deployment, ensuring uninterrupted business continuity.

      Showing 1 - 5 of 17 products
      Soeteck SY-T Online High-frequency UPS, PF1, 10-60kVA -3
      Soeteck Online High-frequency UPS 1kVA-10kVA, PE0.8 -3
      Soeteck SY-T Online High-frequency UPS, PF1, 400-2000kVA -7
      Soeteck SY-T Online High-frequency UPS, PF1, 400-2000kVA -7

      SOETECK SY-T Series UPS, High-frequency Online UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion

      The SOETECK SY-T Series UPS, Online High-frequency UPS, 400kVA-2000kVA, Tower, PF1, True Double Conversion offers unparalleled power protection for mission-critical systems. With a three-phase input/output design, 98.5% efficiency in ECO mode, and flexible battery configurations, it guarantees operational reliability. Advanced DSP controls, modular...

      ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
      SYT400N/A304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
      SYT500N/A304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
      SYT600N/A304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
      SYT1000N/A304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
      SYT1500N/A304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out
      SYT2000N/A304~478VAC (Line Voltage) full load; 304~228VAC (Line Voltage) load derated linearly from 100% to 75%380/400/415 VAC ( Line voltage ); 220/230/240 VAC ( Phase voltage )≥ 97% ( Normal mode ); ≥ 98% ( ECO model ) ; ≥ 97% ( Battery mode )3 phase in, 3 phase out

      SOETECK SY-T Series, High-frequency Online UPS, 10-60kVA, Tower, PF1

      The SOETECK SY-T Series Online High-frequency UPS, 10-60kVA, Tower, PF1 offers robust and efficient power protection for mission-critical systems. With true double-conversion technology, a power factor of 1.0, and three-phase input/output support, it ensures clean and reliable power delivery. Its wide input voltage...

      ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
      SYT10kVA10kVA / 10kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
      SYT20kVA20kVA / 20kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase in, 3 phase out; 3 phase in, 1 phase out; 1 phase in, 1 phase out
      SYT30kVA30kVA / 30kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase N PE
      SYT40kVA40kVA / 40kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase N PE
      SYT60kVA60kVA / 60kW110-300 VAC at 50% load; 176-276 VAC at 100% load3 x 360/380/400/415 VAC (3PH N)95.5% (AC mode) ; 98.5% ( ECO mode) ; 94.5% ( Battery mode )3 phase N PE

      SOETECK SY-T Series, High-frequency Online UPS, 1kVA/2kVA/3kVA, Tower Mounted, PF1

      The SOETECK SY-T Series Online High-frequency UPS, 1kVA/2kVA/3kVA, Tower, PF1, True Double Conversion is a compact, high-performance UPS solution designed for critical applications. Supporting single-phase input and output, it delivers clean and stable power with a power factor of 1.0. With up to...

      ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
      SYT1K1000VA / 1000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase PE
      SYT2K2000VA / 2000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase PE
      SYT3K3000VA / 3000W110~300 VAC(Based on load at 50%); 160~300 VAC (Based on load at 100%)Nominal: 200/208/220/230/240 VAC≧ 92% or ≧ 94% at full charged battery ( AC mode ) ; ≧ 96% at full charged battery ( ECO mode ) ; ≧ 86% or ≧ 91% ( Battery mode )1 phase PE

      SOETECK SY-T Series Winner Pro UPS, High-frequency Online UPS, 1kVA-10kVA, Tower Mount, PF0.9

      The SOETECK SY-T Series Winner Pro UPS, Online High-frequency UPS, 1kVA-10kVA, Tower Mount, PF0.9 is a high-performance power solution designed for critical applications. Its wide input voltage range of 110V–300V, advanced PF 0.9 output, and energy-saving ECO mode make it ideal for small...

      ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
      SYT1kVA1000VA/900W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
      SYT2kVA2000VA/1800W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
      SYT3kVA3000VA/2700W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
      SYT6kVA6000VA/5400W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE
      SYT10kVA10000VA/9000W110-300VAC at 50% load; 160-280 VAC or 170-300 VAC at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase PE

      SOETECK SY-T Series UPS, High-frequency Online UPS, 10kVA-30kVA, Tower Mount, PF0.8

      The SOETECK SY-T Series UPS, Online High-frequency UPS 10kVA-30kVA provides true double-conversion power protection with PF0.8 efficiency. Designed for critical applications, it features a wide input range of 190-520VAC, 50/60Hz frequency conversion, and advanced DSP technology, ensuring reliable, clean, and stable power delivery....

      ModelsPower RatingInput Voltage RangeOutput Voltage RangeEfficiencyWiring
      SYT10kVA10kVA / 8kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase in, 1 phase out
      SYT15kVA15kVA / 12kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase in, 1 phase out
      SYT20kVA20kVA / 16kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase in, 1 phase out
      SYT30kVA30kVA / 24kW190-520 VAC (3-phase) at 50% load; 305-520 VAC (3-phase) at 100% loadNominal: 208/220/230/240 VAC88% - 93% ( AC mode ) ; 83% - 91% ( Battery mode )1 phase in, 1 phase out